Description
Hardware & Electrical Specifications
‑ Model: IC697BEM713 ‑ Part Number: IC697BEM713 ‑ Module Type: Series 90‑70 Genius Bus Expansion Module, occupies one slot on Series 90‑70 rack backplane ‑ Mounting: Standard Series 90‑70 rack; hot‑swap not supported ‑ Backplane power consumption: • +5 VDC: 450 mA maximum ‑ Genius bus interface: Terminal block for primary and redundant secondary Genius trunk cables ‑ Bus baud rate: Fixed 153.6 kbaud ‑ Maximum devices per module: 32 Genius nodes ‑ Bus topology: Trunk‑and‑drop, dual‑cable redundancy supported ‑ Max total trunk cable length: 2000 m (6560 ft) for shielded twisted‑pair ‑ Termination: Genius bus requires 120 Ω terminating resistors at both physical ends of trunk line ‑ Operating mode: Genius Bus‑Master or Bus‑Slave configurable in software ‑ Diagnostics: Module self‑test, bus communication error counter, short‑circuit detection, dual‑cable switch‑over status, node offline fault reporting to CPU ‑ PCB treatment: Conformal coated for dust, moisture and corrosion resistance ‑ Compatibility note: Works with Series 90‑70 CPU family only; cannot install into RX3i / VersaMax racks. Hot‑swap prohibited. After replacement, download hardware configuration, verify Genius node mapping and dual‑cable redundancy function if used.
Environmental Specifications
‑ Operating temperature: 0 ℃ ~ +60 ℃ ‑ Storage temperature: −40 ℃ ~ +85 ℃ ‑ Relative humidity: 5%‑95% non‑condensing ‑ Installation location: Indoor control cabinet, IP20 protection class ‑ EMC compliance: IEC 61000‑6‑2 ‑ Certifications: CE, UL Class I Div 2 hazardous‑location certification
Mechanical Data
‑ Weight: approx 0.65 kg ‑ Dimension: Series 90‑70 standard single‑slot module form‑factor
Main Functions
- Acts as gateway between Series‑90‑70 PLC CPU and Genius distributed I/O bus, scans remote Genius I/O stations and intelligent devices, transfers input/output data between field bus and PLC backplane memory.
- Supports dual‑cable Genius bus redundancy; automatically switches to secondary cable upon primary cable failure without losing I/O data.
- Comprehensive bus‑level diagnostics to locate cable fault, node dropout and short‑circuit issues.
- Front‑panel LED indicators: ‑ Green OK: Module self‑test passed ‑ Red FAULT: Module hardware / configuration fault ‑ BUS A: Primary cable communication activity ‑ BUS B: Redundant secondary cable communication activity
Installation & Wiring Requirements
- Cut off full rack power supply before installation or replacement. Hot‑swap is not permitted. Apply ESD protection during module handling.
- Insert IC697BEM713 into free slot of Series 90‑70 backplane rack and secure module latch.
- Genius bus wiring comply with manual GFK‑0390. Use specified Genius shielded twisted‑pair cable. Install 120 Ω termination resistors at two ends of trunk line. Observe correct A/B polarity for bus signals. Reliable protective‑ground connection is mandatory.
- After replacement: Power‑on rack power, check front‑panel LED status. Download hardware configuration, configure Genius node list. Verify data exchange for all remote I/O nodes; test dual‑cable switch‑over if redundant bus is deployed.
- Replacement note: Confirm total rack backplane power budget. Check bus termination and cable polarity. Full‑system commissioning test is mandatory before putting into service.